Rapid Test Kits

Rapid Test Kits

In many occasions the first step in the process of medical diagnostics is diagnosis with so called Rapid Test Kits. These test kits can help medical professionals make decisions on whether further, more extensive, diagnosis is required, in a fast and reliable manner. Amd works with the best suppliers to provide the most reliable results for this important field of diagnostics.

CLEARVIEW™ One Step Fecal Occult Blood Test Device (Feces)

Detects low levels of human hemoglobin in feces in just 5 minutes Many diseases can cause hidden blood in the feces. This is also known as fecal occult blood (FOB), human occult blood, or human hemoglobin. In early stages, gastrointestinal problems such as colon cancer, ulcers, polyps, colitis, diverticulitis, and

Read More »

CLEARVIEW™ ONE STEP H. PYLORI ANTIGEN TEST DEVICE

Test early. Treat optimally. The Clearview™ H. pylori One Step Antigen Test Device is a simple, rapid stool antigen test that empowers a test-and-treat strategy to test early and treat optimally before symptoms evolve to a more serious condition like ulcers or cancer Sensitivity 100.00% Specificity 100.00%

Read More »

ABON™ SYPHILIS ULTRA RAPID TEST

ABON™ Syphilis Ultra Rapid Test (Whole blood/Serum/Plasma) is a rapid chromatographic immunoassay for the qualitative detection of antibodies (IgG and IgM) to Treponema pallidum (TP) in whole blood, serum and plasma as an aid in the diagnosis of syphilis. Sensitivity 99.5% (98.1%–99.9%) Specificity 99.8% (98.9%–100.0%)

Read More »

ABON™ HCV

Hepatitis C Virus Rapid Test ABON™ Hepatitis C Virus Rapid Tests (Whole blood/Serum/Plasma) are rapid chromatographic immunoassays for the qualitative detection of antibody to Hepatitis C Virus in whole blood, serum, or plasma. Sensitivity >99.53% Specificity 99.78%

Read More »

ABON™ HBsAg

Hepatitis B Surface Antigen Rapid Test ABON™ HBsAg Hepatitis B Surface Antigen Rapid Test (Whole blood/Serum/Plasma) is a rapid test for the qualitative detection of Hepatitis B Surface Antigen (HBsAg) in human whole blood, serum or plasma. Sensitivity 99.80% Specificity 99.20%

Read More »

ABON™ HIV 1/2/0

Tri-line Human Immunodeficiency Virus Rapid Test Device ABON™ HIV 1/2/O Tri-line Human Immunodeficiency Virus Rapid Test Device (Whole blood/Serum/Plasma) is a rapid chromatographic immunoassay for the qualitative detection of antibodies to Human Immunodeficiency Virus (HIV) Type 1, Type 2, and Subtype O in whole blood, serum, or plasma to aid

Read More »

DETERMINE™ TB LAM AG

Saving lives with early TB diagnosis in people living with HIV (PLHIV) The Determine™ TB LAM Ag test empowers you, at the point-of-care, to screen for active TB in HIV positive patients, providing results in just minutes. This rapid test detects the LAM antigen (lipoarabinomannan) in urine samples, assisting you

Read More »

DETERMINE™ SYPHILIS TP (WHO PREQUALIFIED)

Syphilis is caused by the organism Treponema pallidum and is usually transmitted via sexual contact; it can also be transmitted from mother to child (congenital syphilis). It is curable; left untreated, however, it can lead to irreversible neurological and cardiac damage. Determine™ Syphilis TP is an in vitro, visually read,

Read More »

DETERMINE™ HIV EARLY DETECT (WHO PREQUALIFIED)

FAST4WARD ACUTE HIV DETECTION Determine™ HIV Early Detect is the first and only WHO pre-qualified 4th generation rapid diagnostic test (RDT). The 4th gen Determine™ HIV Early Detect sets a new standard in HIV point of care (POC) testing with its exceptional dual accuracy for holistic detection of acute and

Read More »

DETERMINE™ HIV ½ AB (WHO PREQUALIFIED)

Determine™ HIV-1/2 test detects a wide variety of HIV subtypes. This versatility helps healthcare workers across the world diagnose individual infection, monitor HIV prevalence, and enable fast linkage to care. With its simple one-step procedure for serum/plasma or two-step procedure for whole blood, the Determine™ HIV-1/2 is quick and easy

Read More »

Hi! We are part of the 150+ person Amd team. If you have any questions please do not hesitate to contact us.

Start typing and press Enter to search

Shopping Cart

No products in the cart.

Return To Shop

Amd water treatment – The early years 1997-2003

Although originally established as a supplier of Medical Diagnostic products eg. Hepatitis and HIV test kits, we were requested to undertake water treatment engineering. This resulted from a meeting circa November 1997 between Fenton Holland (GM) Amd and Dr. Richard Jones, medical advisor for Texaco and Premier oil 1996-2000. Premier were offshore constructing the Yetagun gas pipeline from the Yetagun field to the coastline near Daminsek village and onto the Thai Border at Yadana. This seven hundred million dollar investment involved an offshore platform, onshore logistics centers and office and a major pipeline both undersea and onshore. Personnel from the UK were brought in to manage the project. Dr. Jones was concerned that of the twenty rental houses required for these personnel none had access to potable water. Follow up microbiological tests confirmed the need. It was decided to install water treatment systems capable of removing potential pathogens. Initially a pilot scale installation was done at 18 E Inya Road. Installation was completed in January 1998. Thereafter numerous other houses and the Premier office had filtration system installed and later maintained by Amd. The Yetagun project was eventually completed in 2000 and the gas flows to Thailand.

Malikha Lodge ( Putao )

This remote northern town was once known as Fort Hertz. Even in 2004 it was an isolated and remote town with trucks from Myitkyina to Putao transiting for up to three weeks! This was one of the reasons we decided to install Australian made steel/zincalume prefabricated tanks, readily transportable on pallets. The hotel was to be built in Mulashidi approximately 7 km outside Putao. After an initial survey in 2004 we decided to pump water from the Nam Lang River, more than 50m below the hotel site. A plateau was carved out of the mountain side enabling the steel tanks and plant room to be built. The water treatment comprised modern filtration and chlorination and utilized Australian Davey pumps known for their small footprint, longevity and economic electrical consumption. In fact, we went on to install Davey pumps in the hundreds throughout Myanmar. The hotel became The Lisu and later The Malikha Lodge. In 2010, we were asked to expand upon our original design and our team once again deployed to Putao. The Malikha Lodge was built as an ECO & adventure Lodge. River Rafting and mountain hiking were envisaged. Those plans were made in 2004, however the full scope was never realized. Nonetheless a first-class lodge was built and bekons those adventure tourists.

Background

Mulashidi is a remote village divided by the Nam Lang River, a pristine blue water river flowing from the Myanmar Himalayas. A water wheel is installed in an adjacent tributary Creek and apparently is used for rice milling and electricity generation for the village was generated. It appears that it was installed circa 1900 and built in Scotland, still operational until the present.

Domestic waste water Coca Cola

The need to properly treat wastewater from a site employing four hundred people was recognized early in the design process. Amd retrofitted a large fiberglass packaged plant featuring several pump stations. The job was complicated by the existence of an old Septic system within the site. Amd’s highly skilled engineers, technicians and designers put their minds together to create an effective solution. The result, a complete, high quality, wastewater treatment system. Amd has further recommended that post effluent treatment would expand the options for disposal of the treated effluent.

 

Coca Cola Hmawbi

When Coca Cola returned to Myanmar after a long absence, they took over a site used to manufacture local soft drink brands. Due to the requirement for expansion they ordered an extremely large prefabricated steel zincalume coated tank from Amd for raw water storage. Further requirements included the need for seismic rating in the event of Earthquakes or Tremors. Amd added a special Antivortex fitting required to meet firefighting codes. Once on site the 640m3 tank was installed in nineteen days including the erection of the necessary scaffolding, meeting all requirements and ready to use.